Finden Sie Iso9001 Generatorsatz, Dieselgenerator, Diesel Stromerzeuger auf Industry Directory, zuverlässige Hersteller / Lieferant / Fabrik aus China

Anfrage-Korb (0)
Home > Produkt-Liste > Andere Diesel Generator > 350kva Diesel-Motor-Generator von perkins Motor angetrieben

350kva Diesel-Motor-Generator von perkins Motor angetrieben

Basisinformation

Modell: AC

Produktbeschreibung

Produktbeschreibung 350kva Dieselmotorengenerator angetrieben durch perkins Motor
Motor: Perkins Motor 2206C-E13TAG2
Lichtmaschine: Leroy somer, stamford, Marathon
Leistung: 350kva / 280kw
Lieferzeit: 2 bis 4 Wochen
Garantie: 1 Jahr oder 1000 Stunden, was immer zuerst kommt

Genset Haupt Technische Daten:

  Genset Model AP400-I
  Prime Power(50HZ) 280KW / 350KVA
  Standby Power(50HZ) 320KW / 400KVA
  Frequency/Speed 50Hz/1500rpm
  Standard Voltage 230V/400V
  Phases Three phases, four wires
  Manufacturer Xiamen AOSIF Engineering LTD. 
Motordaten:
   Manufacturer   Perkins Engines Company Limited
   Model 2206C-E13TAG2
   Engine speed 1500rpm
   Engine power  
   ----------------------------Standby power 368kw
   --------------------------Prime Power 324kw
  Combustion system Direct injection
  Type 4 stroke cycle , Verticle In-line, 6-cylinder
  Aspiration Turbocharged,air-to-air charge cooled
  Bore * Stroke 130*157 mm
  Displacement  12.5 litres
  Compression ratio 16.3:1
  Direction of rotation  Anti-clockwise, viewed 
on flywhee
  Total lubrication system capacity  40 litres
  Total coolant capacity 51.4 litres
  Total dry weight 1478 kg
  Dimensions(Length*Width*Height)  2410*1120*1725 mm
Lichtmaschine Daten:
  Manufacturer  Cummins Generator Technologies(China) Co. Ltd
  Model HCI444E
  Output power 280KW
  AVR model AS440
  Number of phase 3
  Power factor (Cos Phi) 0.8
  Altitude ≤ 1000 m
  Overspeed 2250RPM
  Number of Pole  4
  Exciter type Shunt 
  Insulation class  H
  Protection IP23
  Voltage regulation ±1%
  Waveform distortion no load < 1.5% non-distorting balanced linear load < 5.0%
  Telephone interference THF< 2%
  Bearing   single
  Coupling Direct
Xiamen AOSIF ist ein anerkannter Perkins OEM Partner. So können wir mit Perkins Genset mit
Sehr konkurrenzfähiger Preis und umfassender technischer Support.
Prime power  standby power   Engine brand Engine model alternator brand alternator model Governor
kw kva kw kva          
7 9 8 10 Perkins 403A-11G1* Leroy somer LSA40VS1 M
7 9 8 10 Perkins 403D-11G* Leroy somer LSA40VS1 M
10 13 11 14 Perkins 403A-15G1* Leroy somer LSA40VS2 M
10 13 11 14 Perkins 403D-15G* Leroy somer LSA40VS2 M
12 15 13 17 Perkins 403A-15G2* Leroy somer LSA40S3 M
16 20 18 22 Perkins 404A-22G1* Leroy somer LSA40M5 M
16 20 18 22 Perkins 404D-22G* Leroy somer LSA40M5 M
24 30 26 33 Perkins 1103A-33G Leroy somer LSA42.3VS3 M
36 45 40 50 Perkins 1103A-33TG1 Leroy somer LSA42.3M7 M
48 60 53 66 Perkins 1103A-33TG2 Leroy somer LSA42.3L9 M
52 65 57 72 Perkins 1104A-44TG1* Leroy somer LSA44.3S2 M
64 80 70 88 Perkins 1104A-44TG2* Leroy somer LSA44.3S3 M
64 80 70 88 Perkins 1104C-44TAG1* Leroy somer LSA44.3S3 E
80 100 88 110 Perkins 1104C-44TAG2* Leroy somer LSA44.3S5 E
108 135 119 149 Perkins 1106A-70TG1* Leroy somer LSA44.3M8 E
120 150 132 165 Perkins 1106A-70TAG2* Leroy somer LSA44.3L10 E
144 180 158 198 Perkins 1106A-70TAG3* Leroy somer LSA46.2M3 M
160 200 176 220 Perkins 1106A-70TAG4* Leroy somer LSA46.2M5 E
160 200 176 220 Perkins 1306A-E87TAG3 Leroy somer LSA46.2M5 ECM
180 225 198 248 Perkins 1306A-E87TAG4 Leroy somer LSA46.2L6 ECM
200 250 220 275 Perkins 1306A-E87TAG6 Leroy somer LSA46.2L6 ECM
220 275 242 303 Perkins 1606A-E93TAG4 Leroy somer LSA46.2L9 ECM
240 300 264 330 Perkins 1606A-E93TAG5 Leroy somer LSA46.2VL12 ECM
280 350 308 385 Perkins 2206C-E13TAG2 Leroy somer LSA47.2VS1 ECM
320 400 352 440 Perkins 2206C-E13TAG3 Leroy somer LSA47.2S4 ECM
360 450 396 495 Perkins 2506C-E15TAG1 Leroy somer LSA47.2S5 ECM
400 500 440 550 Perkins 2506C-E15TAG2 Leroy somer LSA47.2M7 ECM
480 600 528 660 Perkins 2806C-E18TAG1A Leroy somer LSA47.2L9 ECM
520 650 572 715 Perkins 2806A-E18TAG2 Leroy somer LSA49.1S4 ECM
600 750 660 825 Perkins 4006-23TAG2A Leroy somer LSA49.1M65 E
640 800 704 880 Perkins 4006-23TAG3A Leroy somer LSA49.1M75 E
800 1000 880 1100 Perkins 4008TAG2A Leroy somer LSA49.1L11 E
1000 1250 1100 1375 Perkins 4012-46TWG2A Leroy somer LSA50.2M6 E
1080 1350 1188 1485 Perkins 4012-46TWG3A Leroy somer LSA50.2L7 E
1200 1500 1320 1650 Perkins 4012-46TAG2A Leroy somer LSA50.2L8 E
1368 1710 1505 1881 Perkins 4012-46TAG3A Leroy somer LSA51.2S55 E
1480 1850 1628 2035 Perkins 4016TAG1A Leroy somer LSA51.2S55 E
1600 2000 1760 2200 Perkins 4016TAG2A Leroy somer LSA51.2M60 E
1600 2000 1760 2200 Perkins 4016-61TRG2 Leroy somer LSA51.2M60 E
1800 2250 1980 2475 Perkins 4016-61TRG3 Leroy somer LSA51.2VL90 E
Genset Standard Configuration

♦ Assembled by Perkins diesel engine and world famous brand alternator
♦ Radiator and fan with safety guard
♦ Automatic control panel and electricity output switch cabinet
♦ Float battery charger and solenoid switch as standard supply scope
♦ Built-in shock pad
♦ Strong and durable hi-strength base frame
♦ Optional voltage rank: 230V/400V, 220V/380V, 127V/220V, 240V/480V etc.

1 Diesel engine

2 Alternator

3 Water tank radiator

4 Automatic control panel

5 Electricity output switch cabinet

6 Built-in shock pad

7 Hi-strength Base Frame
1 Exhaust silencer 2 Bellow 3 Elbow and flange 4 Starting battery
1 ATS 2 Synchronization system 3 Extemal daily fuel tank 4 Silent canopy 5 Trailer
1 Auto fuel pump 2 Fuel and water separator 3 Lub oil heater 4 Coolant heater 5 Fuel drain pump
DeepSea 6020 Controller

DeepSea 6020:
It is a self-starting control module at mains failure and is suitable for controlling a single genset. It provides advanced engine testing and protection functions. This module includes an LCD backlit display that clearly displays the engine running status. The module also includes 7-channel input and 6-channel output. Program can be set through the panel and PC software suite.

Parameters:
Deepsea 6020 controller provides such parameters as generator frequency, idling/overspeed, generator voltage, generator current, engine oil pressure, engine water temperature, flexible fuel level, running hour, battery voltage, start/stop failure, emergency stop, failure to meet operating voltage/frequency, charging failure, magnetic sensor signal loss, low battery voltage, three-phase mains voltage and mains frequency.

Protective functions:
♦ Low oil pressure
♦ High water temperature
♦ High/low voltage
♦ Over speed
♦ Voltage regulator frequency regulator
♦ Emergency stop
♦ Start failure

Product features:
♦ Protection: Automatic start/stop, load switching and genset alarm
♦ Magnetic sensor signal
♦ Parameters setting via PC and panel
♦ Incorporates 4-channel digital input signal and 3-channel analog input signal
♦ 6-channel output signal (4-channel customized output, CAN 6-channel customized output.)
♦ Monitoring of 3-phase generator voltage and mains voltage
♦ Remote loading/unloading
♦ Advanced measurement capabilities
♦ Test button
♦ Switch between mains and genset power
♦ Reasonable structure and button layout
♦ Multiple engine parameters can be tested simultaneously
♦ Module can be configured according to customer demand
♦ IP65 protection (soundproof)

 Multiple air inlets/outlets ensure power performance of the genset.
 Large composite impedance muffler effectively reduces the genset noise.
 Internal high-performance rubber shock absorber and flexible materials can reduce vibration.
 Fuel tank at the bottom can enable the genset to work for 8 hours.
♦  Soundproof enclosure is made by cold steel.
♦  The best powder coating with chemical surface treatment ensure corrosion resistance and coating quality.
♦  Nice appearance and reliable quality.
♦  Stainless steel locks and hinges.
♦  All-weather operation is available.
♦  Fireproof, waterproof and dust-proof
♦  High-performance insulation materials can effectively reduce noise.

♦  Transparent sight glass allows users to clearly see the content of
control panel.
♦  Emergency stop button mounted outside the genset to facilitate
emergency operations.
♦  Coolant filler is set on the top of the enclosure.
♦  Lubricant and coolant pipes are installed at the bottom of the
genset to facilitate replacement with new lubricants and coolants.
♦  Battery is accessible through the access door.
♦  Cooling fan and battery are fully monitored.
♦  Insulated exhaust system is installed inside the genset.
♦  Type of forklift frame is optional.
♦  180° rotatable and detachable door is designed for ease of
maintenance.
♦  Concave lockable access door has a long lifetime.
♦  Lights inside the genset are available for maintenance.
♦  Lugs are mounted at the bottom of the base.
♦  Top lifting mechanism is the standd configuration for high-power
genset.

Our Commitments


 Products and services all comply with ISO8528 and GB/T2820 manufacturing standards.

♦ Management is implemented in strict accordance with ISO9001 Quality Management System and ISO14001 Environmental Management System.
 All products are CE-certified.
 All products have passed rigorous factory test to ensure high quality.
 Product warranty terms are strictly enforced.
♦ High-efficiency assembly and production lines ensure on-time delivery.
 Professional, timely, thoughtful and dedicated services are offered.
 Favorable and complete original accessories are supplied.
 Regular and irregular technical training are provided all year round.
 24/7/365 Customer Service Center provides fast and effective responses to customers’ service demands.

Firmeninformation


Ausstellungsschau
Zertifikatsausstellung
Fertigungsprozess

FAQ

FAQ(Frequently Asked Question):

1.What is your warranty period?

 Our payment terms is 1 year or 1000 running hours whichever comes first. But based on some special project, we can extended our warranty period.

2.Does your generator have global warranty?

 Yes, most of our products like Cummins, Perkins, Doosan power generator enjoy the global warranty service. And the alternator we use like Leroysomer, Stamford, marathon also enjoy the global warranty service, so you do not need to worry about the aftersales service.

3.Can you accept OEM?

 Yes, we can accept OEM.

4.What is your payment  terms?

We can accept T/T 30% in advance, and the balance 70% shall be paid before shipment or L/C at sight, L/C deferred payment terms or west union. 

5.What is your delivery time?

Our normal delivery time is 2 to 5 weeks. But if your order is some special engine and alternator, then the delivery time is longer. 

Kontaktiere uns

Produktgruppe : Andere Diesel Generator